A12-m long and 5-m high wall is constructed of two layers of 1-cm thick sheetrock (k 0.17 w/m °c) spaced 12 cm by wood studs (k 0.11 w/m-°c) whose cross section is 12 cm x 5 cm. the studs are placed vertically 60 cm apart, and the space between them is filled with fiberglass insulation (k = 0.032 wm_°c). the house is maintained at 20°c and the ambient temperature outside is-5°c. taking the heat transfer coefficients at the inner and outer surfaces of the house to be 8.3 and 35 w/m^2 c, respectively. determine a) the thermal resistance of the wall considering a representative section of it b) the rate of heat transfer through the wall.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 12:10
On a average work day more than work place firs are reorted
Answers: 1
question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:20
Describe one experiment in which the glass transition temperature and melting temperature of a totally amorphous thermoplastic material can be determined. show the relevant experimental results in a diagram which should be properly annotated with the two temperatures clearly marked. what is likely to happen to the curve in the diagram if the amorphous polymer is replaced by a thermosetting type?
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
A12-m long and 5-m high wall is constructed of two layers of 1-cm thick sheetrock (k 0.17 w/m °c) sp...