subject

a. Declare an array alpha of 50 components of type int. b. Initialize each component of alpha to -1. c. Output the value of the first component of the array alpha. d. Set the value of the twenty-fifth component of the array alpha to 62. e. Set the value of the tenth component of alpha to three times the value of the fiftieth component of alpha plus 10. f. Use a for loop to output the value of a component of alpha if its index is a multiple of 2 or 3. g. Output the value of the last component of alpha. h. Output the value of the alpha so that 15 components per line are printed. i. Use a for loop to increment every other element (the even indexed...

ansver
Answers: 2

Another question on Computers and Technology

question
Computers and Technology, 21.06.2019 17:20
When developing a stakeholder matrix, the portfolio manager must look at the portfolio governance in order to complete the stakeholder analysis. in your own words, what is the role, interest and expectations of the governance?
Answers: 3
question
Computers and Technology, 22.06.2019 03:30
Write a computer program to calculate the three-phase fault current for a fault at f in figure 1.16, with the network normal, and with one line at a time removedproblems 1.1 write a computer program to calculate the three-phase fault current for a fault at f in figure 1.16, with the network normal, and with one line at a time removed 20 power system relaying from service. the positive-sequence impedance data are given in the accompanying table. use the commonly made assumption that all prefault resistance values are (1.0+j0.0) pu, and neglect all resistance values. calculate the contribution to the fault flowing through the cb b and the voltage at that bus. for each calculated case, consider the two possibilities: cb b2 closed or open. the latter is known as the stub-end fault í• figure 1.16 problem 1.1 system data for figure 1.16 from to positive sequence 0.0+j0.1 0.05j0.15 0.04 j0.2 0.01 jo.i 0.015 + j0.15 0.01 j0.19 0.01 +j0.19 0.03+j0.1 0.0+j0.08 6 6 6 from service. the positive-sequence impedance data are given in the accompanying table. use the commonly made assumption that all prefault resistance values are (1.0 + j 0.0) pu, and neglect all resistance values. calculate the contribution to the fault flowing through the cb b1, and the voltage at that bus. for each calculated case, consider the two possibilities: cb b2 closed or open. the latter is known as the “stub-end” fault.
Answers: 2
question
Computers and Technology, 23.06.2019 01:50
Create a class named majors that includes an enumeration for the six majors offered by a college as follows: acc, chem, cis, eng, his, phys. display the enumeration values for the user, then prompt the user to enter a major. display the college division in which the major falls. acc and cis are in the business division, chem and phys are in the science division, and eng and his are in the humanities division. save the file as majors.java.
Answers: 2
question
Computers and Technology, 23.06.2019 14:30
Which of the following would not be considered a pc? a. mainframe b. desktop c. tablet pc d. laptop
Answers: 2
You know the right answer?
a. Declare an array alpha of 50 components of type int. b. Initialize each component of alpha to -1....
Questions
question
Arts, 27.10.2020 04:20
question
Physics, 27.10.2020 04:20
question
World Languages, 27.10.2020 04:20
Questions on the website: 13722363